VNXe array negotiates FC port as L-Port
VNXe array negotiates FC port as L-Port
Hit an issue today where VNXe array FC ports negotiate to L-port instead of F-port when Fill Word is set to Mode 3 (ARB/ARB then IDLE/ARB). Result – loss of connectivity on the affected link.
Recommended FC Fill Word for VNX/VNXe arrays is Mode 3. Generally it’s a good idea to set them according to best practice as part of each installation. Apparently, when changing Fill Word from legacy Mode 0 (IDLE/IDLE) to Mode 3 (ARB/ARB then IDLE/ARB) array might negotiate as L-port and FC path goes down.
Solution is to statically configure port as F-port in port settings.
A Simple post about problem….
Thanks for Your Wonderful Support and Encouragement
More than 40,000 techies are part of our ARKIT community. Join us today and keep learning Linux, Cloud, Storage, DevOps, and IT technologies.